Add to Cart
Pre&Post heating large nuclear power workpiece by Air cooling induction heating equipment:
Name | Full Digital Air Cooled Induction Heating Machine | ||||||
Work Mode | Manual Mode and Temperature Mode | ||||||
Alarm System | Over Current, Over Voltage, Fail Phase, Driver Board Over Current , Loading abnormal, out off control protection. | ||||||
Special Function | Using DSP and ARM full digital control circuit, the equipment has rich communication interface, support optical fiber, Ethernet, RS485/233, Profibus, CAN and other industrial buses, CAN achieve remote control | ||||||
Model | DIH-60KW | HID-120KW | DIH-200KW | DIH-300KW | |||
Output Power | 60KW | 120KW | 200KW | 300KW | |||
Frequency | 0.5-10khz | 0.5-10KHZ | 0.5-10KHZ | 0.5-10KHZ | |||
Work Voltage | 380V/415v/440v/480v*3phase 50-60hz | ||||||
Power Factor | 0.93 | ||||||
Min Circuit Breaker | 3P-125 | 3P-160 | 3P-200 | 3P-600 | |||
Cooling Way | Air Cooled Type |
"DSP+IGBT+reactanceanalysisfull air-cooleddigital induction heating generator, air cooled coil, system without
water.
Completely eliminate water system failure, lower loss, higher reliability;Air - cooled inductor can be used in some conditions
1. DSP main processor, full digital product
2. PID temperature closed-loop control program that designed for prodution process and workpiece can achieve stable temperature control without overshoot.
Capable of heating workpieces ranging from a few grams to several hundred tons
With an inert link transfer function, it can solve the problem of measurement delay of temperature signal and realize automatic temperature control without overshoot and overheat.
The rate of temperature change is controllable.
Rich enhancements and options for a variety of industrial occasions.
3. Rapid VS Slow: Second level fast temperature control VS A slow rate of temperature change over several days
Perfect match for fast cycle time control of production line.
Full range of temperature change rate can be set from 0.1 °C / H - 1600 °℃ / S.
4. PID parameter automatic setting function, the realization of professional temperature control can not need professional theoretical knowledge of automatic control.
5. Energy control
The energy applied to the workpiece can be controlled and based on this energy temperature control, restriction and protection can be carried out to meet the requirements of high-level and complex process control.
6. Six-pointtemperaturecontrol process operation,temperature curve recording.
7. Full air-cooled clamp coil, full air-cooled frame coil, aircooled induction cable, water-cooled induction cable,water-
cooled frame type coils (choose according to different workpiece and process) Bemad wear-resisting of air cooled extension cable (softconnected sensors)with low loss.preheated 200 °C to 300 ℃, 400 °C to 800 C after heat (can be higher than Curie temperature point) excellent automatic temperature control function (workpiece & process oriented type) automatic setting the PID parameter. precise and stable temperature control, temperature change rate control enhanced process operation module, timing unit of time and temperature change rate of unit of time can be set respectively too/minutes/seconds, surve cohesion is more stable. multi-point temperature control,alarm,automatic heat preservation operation to reduce temperature difference.
8. High current protection type fast navigation plug insulation resistance online detection and protection Balnac online display insulation resistance value, many sets of synchronous operation
9. Engineering experience can be applied to 250 tons weight3 meters diameter large nuclear power components multiple power supply synchronous operation, central control unit control.high reliability
10. The operator only needs to select the heating process program and run the operation, and the presetting of the
process program could be completed by the technician. Start the heat treatment curve automatically with one key, unattended