Multi-Turns Ratios Induction Hardening Transformer
Parameters:
Capacity: 600KVA
Suitable Power:60KW-100KW
Working Frequency:30-80Khz
Transformer Ratios: 8-16turns
Secondary coil: 1 and 2 Turns
Application: Induction Hardening, Induction Heating
Variable's Transformer Connection:
In order to give more options for you to connect different coils, so we made a adjustable Transformer for you, the connection way as follows:
Secondary connection at the front of the Transformer:
Have 1 turn and 2 turns Secondary connection copper plate.
Primary connection as the back of the transformer:Com is comm on Port: Connect the Black one, this is must be connect it,
Red port is options (8Turns,10Turns,12Turns, 14Turns,16Turns).
Coil length connection From Long to Short sequence as follows:
8TURNS-10TURNS-12TURNS-14TURNS-16TURNS
Means 8 turns can connect longest coil length, then will be 10turns--12turns-14turns --16turns.
So if you choose 2 turns primary connection, then transformer ratios as follows:
8:2(can as 4:1) 10:2(can as 5:1) 12:2(6:1) 14:2(7:1) 16:2(8:1)
If you choose 1 turn primary connection, then transformer ratios as follows:
8:1 10:1 12:1 14:1 16:1
If use the same coil, Transformer ratios is smaller, Frequency will higher. Transformer ratios is bigger, the frequency will be lower.
( Coil is smaller, connect the transformer ratio is bigger, coil is bigger, connect the transformer ratios is smaller)