Infrared Thermometer
Features:
1. Induction heating Machine Heating, power (B mode), switch control (E mode) two modes are optional, when the power mode is inconvenient, switch to the general upper/lower limit, switch (relay) mode control, one machine can be dual-use , Strong adaptability.
2. A section of temperature control, used for induction heating equipment, closed-loop power control, or temperature control between upper/lower limits (relay switch mode). ; Can also be used for heating wire heating and other electric heating equipment,upper / lower temperature limit, relay switch mode temperature control.
A In closed-loop power control mode (mode B), there are three relay switch alarm terminals, namely: preheat alarm, constant temperature alarm, standby switch to be started by the control device, and an external terminal for automatic work emergency stop, (short-circuit effective, Do not connect voltage)
B Relay switch mode temperature control (E mode), there are four relay switch alarm terminals, namely: upper limit alarm, lower limit alarm,standby switch to be started by the control device, multi-function alarm, and an external terminal for automatic work emergency stop, (Short-circuit is effective, do not connect voltage)
3. (E mode) No control Temperature, only for temperature monitoring, turn on the foot switch of the machine, use the buzzer of the machine or the multi-function alarm terminal, and the alarm prompts.
4 .(E mode) The multi-function alarm functions are: 2-1/H (the measured temperature is higher than the upper limit temperature alarm), →2-2/HL ( Reach the upper limit alarm and the self-locking is maintained until the lower limit temperature is stopped), →2-3 /H=L (As long as the temperature is between the upper/lower set temperature, there is an alarm), → Enter 2-4/-HL- (The temperature is higher than the upper limit set temperature or lower than the lower limit set temperature, there is an alarm) , This terminal cannot be turned off, and the local beeper that is synchronized with it can be turned off, but the set beep cannot be turned off.
5. Constant temperature heating, or timing heating can be selected, or stop at the temperature.
6. The fiber optic thermometer is fully coaxial laser aiming, especially suitable for small targets. The non-fiber thermometer is two aiming points, which are subject to the midpoint of the two points.
7 Simple operation and clear interface
Paramaters:
Voltage: 220-240VAC Power consumption< 10W
Distance coefficient :75:1
Repeatability precision: 1 ℃
Fiber length : 1.4M ( standard)
Timing setting or temperature setting can be options
Laser sighting : any switch , such as laser sighting enable 30 seconds
laser sighting switch without any operation , will automatically turn off (15
seconds for the standard set ) , others requirements according to customer to set.
Working temperature: Host ≤ 50 ℃ Humidity : 10% -80% Fiber - optic
probe: temperature ≤ 150 ° C Humidity : 10% -80%
Dimension: Main part 240 ( L) x 180 ( W ) × 110mm ( H) mm fiber optic probe :
diameter 20 x 90mm.
Data Sheet:
Mode | Temperature range | Structure model |
ORD-C | 100-800C | Non fiber-optic 1 points aim ( Special for Tin and ALum) |
STB/E300-1000 | 300-1000 ℃ | Fiber-optic Coaxial aim |
STB/E400-1300 | 400-1300 ℃ | Fiber-optic Coaxial aim |
STB/E500-1500 | 500-1500 ℃ | Fiber-optic Coaxial aim |
STB/E 700-2200 | 700-2200 ℃ | Fiber-optic Coaxial aim |
After-sale service:
1. Warranty time: Within 18 months from the date of delivering, 12months from date of receiving.
2. Within warranty all parts are free for customer, any fault caused by non-artificial reason, any quality problems such as design, manufacture, or procedure occurs, We shall provide replacement parts after detecting the faults.
3. If any big quality problems occurs out of the guarantee period, we will send maintenance
technician to provide visiting service after checking with the customer and charge for a favorable price.
5. We will provide a lifetime cost price to the buyer with the materials and spare parts used in system operation, equipment maintenance.
6. The above mentioned are only basic aftersale service requirements,we will make more promises related to quality assurance and operation guarantee.